Energyflex® PV H1Z2Z2-K Cable (1.5kV DC)

Description
Energyflex® cables are designed to comply with the international standards of the solar plants.
They are dedicated to the photovoltaic system direct current (D.C.) side with a nominal D.C. voltage of 1.5 kV and a maximum D.C. voltage of 1.8 kV.
These cables are suitable for permanent outdoor long-term use, under variable and harsh climate conditions.
They are designed and tested to operate at a normal maximum conductor temperature of 90°C and for 20,000 hours up to 120°C. Therefore, the expected period use is 30 to 40 years under normal usage conditions (lifetime acc. to Arrhenius-Diagram).
Description
They are dedicated to the photovoltaic system direct current (D.C.) side with a nominal D.C. voltage of 1.5 kV and a maximum D.C. voltage of 1.8 kV.
These cables are suitable for permanent outdoor long-term use, under variable and harsh climate conditions.
They are designed and tested to operate at a normal maximum conductor temperature of 90°C and for 20,000 hours up to 120°C. Therefore, the expected period use is 30 to 40 years under normal usage conditions (lifetime acc. to Arrhenius-Diagram).
Standards
International : EN 50618; IEC 62930Description
Application
These state-of-art 1.5kV D.C. cross-linked Energyflex® cables offer exceptional performances, easy installation and long-term reliability for solar plant. They link photovoltaic panels for Utility-Scale solar plants or rooftops, and also connect them to the array box (if existing), or potentially to the inverter.
|
: | Energyflex® |
|
: | H1Z2Z2-K |
|
: | EN 50618:2014 |
Design
- Single core solar cable with low smoke, halogen free, cross-linked insulation and sheath.
- String Harness according to IEC 62548 Photovoltaic (PV) arrays - Design requirements.
Recommended Use
- Renewable Energies; Solar Plants.
- Intended for permanent use outdoor and indoor.
- Installation can be fixed or free movable / free hanging, and also in cable trays and conduits.
- These cables have a suitable behaviour in water : tests of Annexes D and E of H07RN8-F AD8 cables (100 days at 50 °C under 1 kV AC without breakdown) , and additionnal test of 1,5 year in hot water (85°C) under 1 kV DC without breakdown. They are suitable for submerged installations with a maximum cumulated immersion period of 6 months / year.
COMPLEMENTARY PRODUCTS
Energyflex® PV cables are part of the KEYLIOS® product range that includes:
- PV LV-DC String Harnesses
- LV-DC Aluminium core cable - unarmoured for above ground installation
- LV-DC Aluminium core cable - amoured for direct buried installaiton
- MC4 Connectors
- MV-AC Underground cables
Characteristics
Construction characteristics | |
---|---|
Conductor flexibility | Flexible class 5 |
Insulation | Cross-linked (XL) HFFR acc. to EN 60811 and EN 60216-1-2 |
Outer sheath | Cross-linked (XL) HFFR acc. to EN 60811 and EN 60216-1-2 |
Halogen free | IEC 60754-1/IEC 60754-2 |
Conductor material | Tin Coated Copper Class 5 acc. To EN 60228 |
Electrical characteristics | |
Rated Voltage Uo/U (Um) | 1.0/1.0 (1.2) kV AC - 1.5/1.5 (1.8) kV DC |
Usage characteristics | |
Operating temperature, range | -40 .. 90°C |
Max. conductor temperature in service | 120°C |
Short-circuit max. conductor temperature | 250°C |
Gases corrosivity | IEC 60754-2 |
Gases toxicity | IEC 60754 |
Smoke density | IEC 61034-1-2 |
Ozone resistance | EN 50396:2005 |
Weather resistance | Excellent |
Flame retardant | IEC 60332-1 |
U.V resistance | EN 50289-4-17 method A, for 720h. Nexans prestige test 4000h |
Water proof | Passed 100 days 50°C water immersion test of EN 50525-2-21 annex D and E |
Resistance to vibrations | Condition AH 3 (sever idustrial conditions) acc. to HD 60364-5-52 |
Specific characteristics | |
See all products | |
|
Products and services
Docs and info
-
Current rating temperature
Ambient temperature = 60°C
Maximum conductor temperature = 120°C
- TECHNICAL INFORMATION (1/3)
- TECHNICAL INFORMATION (2/3)
- TECHNICAL INFORMATION (3/3)
Related links
Related documents
Selling information
"Want to know more about the environmental impact of the product during its life cycle ?
Please contact:: sustainable.development@nexans.com and discover the PEPecopassport® declaration available with all the details”
Declaration of Performance
Declaration of Performance No: 1000199-FRAN
- Certification Date: 17/12/2019
- AVCP (Assessment and Verification of Constancy of Performance): System 3
- Notified body : NB 1812
- Declared performance: Reaction to fire Dca -s2,d2,a1 according to EN50575:2014+A1:2016
Nexans ref. | Country ref. | Product Name |
20056098-901-05 | 0505305 | ENERGYFLEX® 1x4mm² |
20056098-927-05 | 0505315 | ENERGYFLEX EN50618 1x4 ONE Stripe RED D500 |
20056198-901-05 | 0505325 | ENERGYFLEX® 1x6mm² |
20056198-927-05 | 0505335 | ENERGYFLEX 1X6 EN50618 One Stripe RG D500 |